Category 6a U/UTP 4 Pair Cable


Norden Category 6A U/UTP cables exceed Category 6A/Class EA specification. It is tested to 500MHz frequency range and designed to support 10 Gigabyte applications to full 100m.

Extremely high pair-balance providing excellent EMC  (Electro Magnetic compatibility),  minimizing radiation, maximizing noise immunity and providing high alien cross talk performance to U/UTP (Unshielded Twisted Pair) cabling systems.

 

COMPLIANCE

IEEE 802.3an :2006 (10GBASE-T)

ANSI/TIA-568-C.2:2009 Category 6A

ISO/IEC-11801, 2nd Edition Class EA

IEC 61156-5:2002 Category 6A

LSZH: IEC 60332-1, IEC 60754, IEC 61034

MATERIAL CONSTRUCTION & DESIGN

Bare Copper

Conductor Material:

0.57mm (D) norm, 23 AWG

Conductor Size:

Solid

Conductor Construction:

HDPE

Insulation Material:

1.03 mm nom.

Insulation O.D.:

Solid/Stripe

Conductor Unit Identifcation:

Per TIA/EIA 568-B

Colour Code:

Pairs

Conductor Unit Lay-Up:

8

Total Number of Wires:

LS0H Halogen free fame retardant or PVC

Outer Jacket Material:

0.65±0.05mm, 6.9±0.4mm

Outer jacket thickness & Ex. Diameter:

Per requirement

Outer Jacket Colour:

Yes

Rip Cord:

N/A

Overall Drain-Wire Material:

N/A

Overall Drain-Wire Construction:

 

MECHANICAL, ELECTRICAL & TRANSMISSION CHARACTERISTICS

110 N/mm2max.

Pulling Force:

25ns/100m max.

Delay Skew:

85 db min @ 30-100 MHz  85-20log(f/100) @100-500 MHz

Coupling Attenuation:

100±6 Ω @ 1-500 MHz

Characteristic Impedance:

72Ω/Km max.

DC Resistance:

2% max.

Resistance Unbalance:

45 pF/m nom.

Capacitance:

1500 pF/Km max.

Cap. Unbalance (Wire to Ground):

1.5KV/ minute min.

Dielectric Strength:

67%

Velocity of Propagation (NVP):

5000 MΩ•Km min.

Insulation Resistance:

N/A

Transfer Impedance:

8 x OD mm

Short Term Bend Radius :

4 x OD mm

Long Term Bend Radius :

-20 to +60˚C

Temperature Operating Range :

0 to +50˚C

Installation Temperature Range :

 

ELECTRICAL PERFORMANCE CHARACTERISTICS

Cat. 6A Un-screened Pair Horizontal Cables*

PSELFEXT
dB

ELFEXT
dB

ACR
dB

RL
dB

PS NEXT 
dB

NEXT 
dB

Attenuation
dB/100m@20°C

Freq.
MHz

80

84

84.6

26

83.3

86.3

1.7

1

78

81

75.6

29

83

85

3.4

4

73

76

71.9

31

74.3

77.3

5.4

10

67

70

62.4

30

67

70

7.6

20

63

65

58.3

29.8

65

68

9.7

31.25

52.8

55

47.3

27.1

62.3

65.3

18

100

51.5

53.5

38.4

26

59.8

62

23.6

150

46

49

31.6

25

57.2

59

27.4

200

41

44

26.6

25.2

54.6

57.6

31

250

36.6

39.6

20.3

24

52

55

34.2

300

34

37

13

21.8

51.8

53

40

400

33

35

9.8

21.8

50

52

42.2

500

*Supplied cables meet the minimum Cat. 6A transmission requirements as per IEC 61156-5 Ed. 2

ORDERING INFORMATION

LENGTH (STANDARD)

DESCRIPTION

PART NUMBER

305 mtr

Category 6a U/UTP 4 Pair Cable PVC

114-10001104X

305 mtr

Category 6a U/UTP 4 Pair Cable LSZH

114-10002104X

X:BK(Black), BL(Blue), GN(Green), GY(Gray), RD(Red), WH(White), YL(Yellow)

PACKING INFORMATION

Dimension
(cm)

G.W
(kg)

N.W
(kg)

Packing Mode

Cable Length
(Metre)

34.0 x 34.0 x 34.0

16.8

15

Ply Reel

305

56.0 x 56.0 x 25.0

55.6

49.3

Ply Reel

1000

 